Invalid Parameters Were Detected For An Operation Macos Error Code

  • 1Exceptions
    • 1.1Faults
      • 1.1.9Page Fault
    • 1.2Traps
    • 1.3Aborts
  • 2Selector Error Code
    • 2.1Legacy
  • 3See Also

Exceptions as described in this article are generated by the CPU when an 'error' occurs. Some exceptions are not really errors in most cases, such as page faults. Exceptions are a type of interrupt.

Sep 15, 2010  Subject: ntdev DeviceIoControl failing with ERRORINVALIDPARAMETER Hi All, I created an IOCTL in my user app as well as in the driver with the following code: #define IOCTLKEYBOARDTRANSFERDATA CTLCODE(FILEDEVICEKEYBOARD, 0x800, METHODBUFFERED, FILEREADDATA ) Now from my user app: I call the following code: char output100. Long-desc = Try the operation again. If the problem persists, contact your network administrator.; kMsgEapAMErrTimeout 1301 Short-desc = Timeout. Long-desc = The operation exceeded the time limit. Try the operation again.; kMsgEapAMErrIncomplete 1302 Short-desc = Authentication not completed. Long-desc = Try the operation again. Acronis Cyber Protect Cloud, Acronis Cyber Backup: SQL database backup fails with 'An invalid file has been detected' Acronis Cyber Backup 12.5: backup to Quantum Scalar tape library fails Acronis Cyber Backup: attempt to browse or delete mobile device backup fails with 'Internal error.

Mar 26, 2020  This document scanner is compatible with Windows, Mac, and Linux, meaning it’ll work with any networking system your office uses. Your employees will be able to tackle even the largest workloads quickly and easily, thanks to its 50-sheet capacity automatic document feeder and a working speed of 30 pages per minute. What is the best scanner software for Mac? VueScan Scanner Software is recognized as the best scanner software for macOS because of it’s compatability with over 6000 scanners. That way you don’t need to find and download individual scanner drivers, especially because on macOS Catalina so many manufacturers didn’t release updated drivers. Aug 02, 2019  The Best Scanners for Macs. Finding the right scanner for your Apple computer can be tricky. Here's what you need to know, along with our top Mac-friendly picks. Oct 14, 2019  “One of the main things that Apple has done in Catalina is remove support for running 32-bit programs. Scanners don’t wear out and people like to use their scanners for a long time, sometimes for 10 or 15 years. However, most vendor-supplied scanner drivers are 32-bit programs on Mac OS and don’t work on Catalina. All Mac OS Catalina printers can be used for Mac computer because MacOS Catalina itself is the Mac operating system. It means those printers are useable for Mac desktop too. So, the first best printer for Mac is HP LaserJet M477fdn, However, HP company played a major role in producing multiple printers for Mac and HP has several types of printers. Best document scanner for mac catalina.

Exceptions are classified as:

  • Faults: These can be corrected and the program may continue as if nothing happened.
  • Traps: Traps are reported immediately after the execution of the trapping instruction.
  • Aborts: Some severe unrecoverable error.

Some exceptions will push a 32-bit 'error code' on to the top of the stack, which provides additional information about the error. This value must be pulled from the stack before returning control back to the currently running program. (i.e. before calling IRET)

Name Vector nr. Type Mnemonic Error code?
Divide-by-zero Error 0 (0x0) Fault #DE No
Debug 1 (0x1) Fault/Trap #DB No
Non-maskable Interrupt 2 (0x2) Interrupt - No
Breakpoint 3 (0x3) Trap #BP No
Overflow 4 (0x4) Trap #OF No
Bound Range Exceeded 5 (0x5) Fault #BR No
Invalid Opcode 6 (0x6) Fault #UD No
Device Not Available 7 (0x7) Fault #NM No
Double Fault 8 (0x8) Abort #DF Yes (Zero)
Coprocessor Segment Overrun 9 (0x9) Fault - No
Invalid TSS 10 (0xA) Fault #TS Yes
Segment Not Present 11 (0xB) Fault #NP Yes
Stack-Segment Fault 12 (0xC) Fault #SS Yes
General Protection Fault 13 (0xD) Fault #GP Yes
Page Fault 14 (0xE) Fault #PF Yes
Reserved 15 (0xF) - - No
x87 Floating-Point Exception 16 (0x10) Fault #MF No
Alignment Check 17 (0x11) Fault #AC Yes
Machine Check 18 (0x12) Abort #MC No
SIMD Floating-Point Exception 19 (0x13) Fault #XM/#XF No
Virtualization Exception 20 (0x14) Fault #VE No
Reserved 21-29 (0x15-0x1D) - - No
Security Exception 30 (0x1E) - #SX Yes
Reserved 31 (0x1F) - - No
Triple Fault - - - No
FPU Error Interrupt IRQ 13 Interrupt #FERR No

Exceptions

Faults

Divide-by-zero Error

The Divide-by-zero Error occurs when dividing any number by 0 using the DIV or IDIV instruction. Many OS developers use this exception to test whether their exception handling code works. This exception may also occur when the result is too large to be represented in the destination.

The saved instruction pointer points to the DIV or IDIV instruction which caused the exception.

Bound Range Exceeded

This exception can occur when the BOUND instruction is executed. The BOUND instruction compares an array index with the lower and upper bounds of an array. When the index is out of bounds, the Bound Range Exceeded exception occurs.

The saved instruction pointer points to the BOUND instruction which caused the exception.

Invalid Opcode

The Invalid Opcode exception occurs when the processor tries to execute an invalid or undefined opcode, or an instruction with invalid prefixes. It also occurs when an instruction exceeds 15 bytes, but this only occurs with redundant prefixes.

The saved instruction pointer points to the instruction which caused the exception.

Device Not Available

Invalid Parameters Were Detected For An Operation Macos Error Code

The Device Not Available exception occurs when an FPU instruction is attempted but there is no FPU. This is not likely, as modern processors have built-in FPUs. However, there are flags in the CR0 register that disable the FPU/MMX/SSE instructions, causing this exception when they are attempted. This feature is useful because the operating system can detect when a user program uses the FPU or XMM registers and then save/restore them appropriately when multitasking.

The saved instruction pointer points to the instruction that caused the exception.

Invalid TSS

An Invalid TSS exception occurs when an invalid segment selector is referenced as part of a task which, or as a result of a control transfer through a gate descriptor, which results in an invalid stack-segment reference using an SS selector in the TSS.

When the exception occurred before loading the segment selectors from the TSS, the saved instruction pointer points to the instruction which caused the exception. Otherwise, and this is more common, it points to the first instruction in the new task.

Error code: The Invalid TSS exception sets an error code, which is a selector index.

Segment Not Present

The Segment Not Present exception occurs when trying to load a segment or gate which has it's Present-bit set to 0.However when loading a stack-segment selector which references a descriptor which is not present, a Stack-Segment Fault occurs.

The saved instruction pointer points to the instruction which caused the exception.

Error code: The Segment Not Present exception sets an error code, which is the segment selector index of the segment descriptor which caused the exception.

Stack-Segment Fault

The Stack-Segment Fault occurs when:

  • Loading a stack-segment referencing a segment descriptor which is not present.
  • Any PUSH or POP instruction or any instruction using ESP or EBP as a base register is executed, while the stack address is not in canonical form.
  • When the stack-limit check fails.

This exeption is not part of segment not present exeption because of the need to push eip,cs,eflags,esp,ss to the stack is no longer valid becuase of the ss's gdt entry (or the ss itself) had to be buggy in the first place for this exeption to occur , so one must declare this exeption as a task switch interrupt and setting up tss for it. The saved instruction pointer points to the instruction which caused the exception.


Error code: The Stack-Segment Fault sets an error code, which is the stack segment selector index when a non-present segment descriptor was referenced. Otherwise, 0.

General Protection Fault

A General Protection Fault may occur for various reasons. The most common are:

  • Segment error (privilege, type, limit, read/write rights).
  • Executing a privileged instruction while CPL != 0.
  • Writing a 1 in a reserved register field.
  • Referencing or accessing a null-descriptor.
  • Trying to access an unimplemented register (like: mov cr6, eax)

The saved instruction pointer points to the instruction which caused the exception.

Error code: The General Protection Fault sets an error code, which is the segment selector index when the exception is segment related. Otherwise, 0.

To be more specific, being a file extension for AVCHD (Advanced Video Coding High Definition) video, MTS generally adopts H.264 video coding and AC-3 audio coding, and supports 1080i and 720p, with full HD standard 1920 x 1080/1440 x 1080 for resolution. Why to Convert MTS Videos?Nowadays, it is usual to shoot some awesome video chips for a wonderful vacation, graduation ceremony, happy parties, weddings or other meaningful moments with the high definition camera. What making many people anxious is that the videos shot by HD camcorder are in MTS format, which cannot be directly played on Mac, not to mention iPhone, iPad, AppleTV. Best video converter for mac catalina. In brief, MTS format is a currently booming high-definition (HD) video format mainly applied in HD camcorder such as Sony, Canon, Panasonic and JVC. Basic Knowledge of MTSBefore answering the question, let's have a basic understanding of MTS video first.

Page Fault

A Page Fault occurs when:

  • A page directory or table entry is not present in physical memory.
  • Attempting to load the instruction TLB with a translation for a non-executable page.
  • A protection check (privileges, read/write) failed.
  • A reserved bit in the page directory or table entries is set to 1.

The saved instruction pointer points to the instruction which caused the exception.

Error code

The Page Fault sets an error code:

Skype for business free download - Skype, Call Recorder for Skype, Skype Spanish/English, and many more programs. Dec 01, 2016  The messaging app is integrated into Wayne Connect and is also available for download for both macOS and PC. All Wayne Connect users have access to Skype for Business and may log in with their AccessID and password. To access Skype for Business in your web browser click the S icon in the upper right hand corner in Wayne Connect. Desktop client. All Wayne Connect users may now download Skype for Business. May 28, 2020  To install Skype for Business on Mac: Click the Download button. Click Save to copy the disc image file to your computer. Double click the PKG image file. Follow the on screen instructions. Download and install Skype for Business on Mac. Skype for Business makes it easy to connect and collaborate with coworkers and business partners around the world: Start instant message conversations and voice or video calls. See when your contacts are available online. Jun 30, 2020  The latest version of Skype For Business is 16.28 on Mac Informer. It is a perfect match for the Internet Tools category. The app is developed by Microsoft and its user rating is 2 out of 5. Download macos skype for business download.

Length Name Description
P 1 bit Present When set, the page fault was caused by a page-protection violation. When not set, it was caused by a non-present page.
W 1 bit Write When set, the page fault was caused by a write access. When not set, it was caused by a read access.
U 1 bit User When set, the page fault was caused while CPL = 3. This does not necessarily mean that the page fault was a privilege violation.
R 1 bit Reserved write When set, one or more page directory entries contain reserved bits which are set to 1. This only applies when the PSE or PAE flags in CR4 are set to 1.
I 1 bit Instruction Fetch When set, the page fault was caused by an instruction fetch. This only applies when the No-Execute bit is supported and enabled.

In addition, it sets the value of the CR2 register to the virtual address which caused the Page Fault.

x87 Floating-Point Exception

The x87 Floating-Point Exception occurs when the FWAIT or WAIT instruction, or any waiting floating-point instruction is executed, and the following conditions are true:

  • CR0.NE is 1;
  • an unmasked x87 floating point exception is pending (i.e. the exception bit in the x87 floating point status-word register is set to 1).

The saved instruction pointer points to the instruction which is about to be executed when the exception occurred. The x87 instruction pointer register contains the address of the last instruction which caused the exception.

Error Code: The exception does not push an error code. However, exception information is available in the x87 status word register.

Invalid

Alignment Check

An Alignment Check exception occurs when alignment checking is enabled and an unaligned memory data reference is performed. Alignment checking is only performed in CPL 3.

Alignment checking is disabled by default. To enable it, set the CR0.AM and RFLAGS.AC bits both to 1.

The saved instruction pointer points to the instruction which caused the exception.

SIMD Floating-Point Exception

The SIMD Floating-Point Exception occurs when an unmasked 128-bit media floating-point exception occurs and the CR4.OSXMMEXCPT bit is set to 1. If the OSXMMEXCPT flag is not set, then SIMD floating-point exceptions will cause an Undefined Opcode exception instead of this.

The saved instruction pointer points to the instruction which caused the exception.

Error Code: The exception does not push an error code. However, exception information is available in the MXCSR register.

Traps

Debug

The Debug exception occurs on the following conditions:

  • Instruction fetch breakpoint (Fault)
  • General detect condition (Fault)
  • Data read or write breakpoint (Trap)
  • I/O read or write breakpoint (Trap)
  • Single-step (Trap)
  • Task-switch (Trap)

When the exception is a fault, the saved instruction pointer points to the instruction which caused the exception. When the exception is a trap, the saved instruction pointer points to the instruction after the instruction which caused the exception.

Error code: The Debug exception does not set an error code. However, exception information is provided in the debug registers (CPU_Registers_x86#Debug_Registers).

Breakpoint

A Breakpoint exception occurs at the execution of the INT3 instruction. Some debug software replace an instruction by the INT3 instruction. When the breakpoint is trapped, it replaces the INT3 instruction with the original instruction, and decrements the instruction pointer by one.

The saved instruction pointer points to the byte after the INT3 instruction.

Overflow

An Overflow exception is raised when the INTO instruction is executed while the overflow bit in RFLAGS is set to 1, or when the result of div/idiv insructions is bigger than 64 bit /32 bit / 16 bit /8bit depending on the instruction operand size .( only if bigger than the operand size.)

The saved instruction pointer points to the instruction after the INTO instruction, or when an div/idiv is the cuase of the exeption , the insruction pointer that pushed points to the faulty insruction.

Aborts

Double Fault

A Double Fault occurs when an exception is unhandled or when an exception occurs while the CPU is trying to call an exception handler. Normally, two exception at the same time are handled one after another, but in some cases that is not possible. For example, if a page fault occurs, but the exception handler is located in a not-present page, two page faults would occur and neither can be handled. A double fault would occur.

A double fault will always generate an error code with a value of zero.

The saved instruction pointer is undefined. A double fault cannot be recovered. The faulting process must be terminated.

In several starting hobby OSes, a double fault is also quite often a misdiagnosed IRQ0 in the cases where the PIC hasn't been reprogrammed yet.

Machine Check

The Machine Check exception is model specific and processor implementations are not required to support it. It uses model-specific registers to provide error information. It is disabled by default. To enable it, set the CR4.MCE bit to 1.

Machine check exceptions occur when the processor detects internal errors, such as bad memory, bus errors, cache errors, etc.

The value of the saved instruction pointer depends on the implementation and the exception.

Triple Fault

Main article:Triple Fault

The Triple Fault is not really an exception, because it does not have an associated vector number. Nonetheless, a triple fault occurs when an exception is generated when attempt to call the double fault exception handler. It results in the processor resetting. See the main article for more information about possible causes and how to avoid them.

Selector Error Code

Length Name Description
E 1 bit External When set, the exception originated externally to the processor.
Tbl 2 bits IDT/GDT/LDT table This is one of the following values:
Value Description
0b00 The Selector Index references a descriptor in the GDT.
0b01 The Selector Index references a descriptor in the IDT.
0b10 The Selector Index references a descriptor in the LDT.
0b11 The Selector Index references a descriptor in the IDT.
Index 13 bits Selector Index The index in the GDT, IDT or LDT.

Legacy

The following exceptions happen on outdated technology, but are no longer used or should be avoided. They apply mostly to the intel 386 and earlier, and might include CPUs from other manufacturers around the same time.

Invalid Parameters Were Detected For An Operation Mac Os Error Code 2168 0002

FPU Error Interrupt

In the old days, the floating point unit was a dedicated chip that could be attached to the processor. It lacked direct wiring of FPU errors to the processor, so instead it used IRQ 13, allowing the CPU to deal with errors at it's own leasure. When the 486 was developed and multiprocessor support was added, the FPU was embedded on die and a global interrupt for FPUs became undesirable, instead getting an option for direct error handling. By default, this method is not enabled at boot for backwards compatibility, but an OS should update the settings accordingly.

Coprocessor Segment Overrun

When the FPU was still external to the processor, it had separate segment checking in protected mode. Since the 486 this is handled by a GPF instead like it already did with non-FPU memory accesses.

Invalid Parameters Were Detected For An Operation Mac Os Error Code 36

See Also

Invalid Parameters Were Detected For An Operation Mac Os Error Code 36 Can T Be Read Or Written

External Links

  • Intel速 64 and IA-32 Architectures Software Developer's Manual, Volume 3 (System Programming Guide), Chapter 6 (Interrupt and exception handling)

Invalid Parameters Were Detected For An Operation Mac Os Error Code 8076

Retrieved from 'https://wiki.osdev.org/index.php?title=Exceptions&oldid=23643'